PanelView 600 replacement: first, which 600 do you have?

"PanelView 600" names three different products: the old Standard 600 (2711-), the PanelView Plus / Plus 6 600 (2711P-), and the PanelView Component C600 (2711C-). The catalog number on the rear label settles it — and each family has a different replacement story.

Put a screen on a phone meanwhile →

Identify by catalog number

Rear label starts withYou haveStatusYour path
2711-K6C / -B6C / -T6CPanelView Standard 600Retired; PanelBuilder32 goneRebuild on Plus 7 or PanelView 800 (below)
2711P-T6 / -K6 / -B6PanelView Plus 600 / Plus 6 600Plus 6 line discontinued end of 2022Plus 7 — the .mer carries forward
2711C-T6C / -T6TPanelView Component C600RetiredPanelView 800 — CCW imports the app

Standard 600 (2711-): the rebuild case

Same story as the 550: PanelBuilder32 projects (.pba) don't convert, so the application is rebuilt by hand on the new platform. Rockwell's migration mapping sends the keypad and keypad-and-touch variants (K6C/B6C) to the 6.5″ Plus 7 Performance with adapter kit 2711P-RAAK7 for the cutout, and the touch-only T6C to the 6″ Plus 7 Standard with no adapter. Check the comms variant on the label — DH-485 and RS-232 units need the comms plan settled before you order hardware.

Plus 600 / Plus 6 600 (2711P-): the friendly case

Here the application survives: .mer projects carry forward to a Plus 7 with firmware and FactoryTalk View version care. If all you have is the .mer runtime and the original .apa archive is lost, recover it from the terminal before it dies completely. The Plus 1000 decision guide walks the same trade-offs at bigger screen sizes, and the obsolescence timeline shows where every 2711P generation stands.

Component C600 (2711C-): the import case

The official successor is the PanelView 800 — Connected Components Workbench imports PanelView Component applications, screen sizes map one-to-one, and CCW is a free download. Of the three 600s, this is the one where migration is genuinely routine.

Keep producing while you wait

Have the FactoryTalk project export? Drop it into our free HMI project converter — it runs in your browser, the file never leaves your PC, and every display becomes a page of buttons, indicators and values for the app, with the real tag names already in place.

Today, from a phone: the free LineKeeper app for iPhone and iPad connects to your ControlLogix or CompactLogix over EtherNet/IP and reads the controller's own tag list — no export files, no configuration. Build a dashboard and an operator panel with start/stop buttons in about 15 minutes, mount a spare iPad in full-screen panel mode, and the operator has a screen before the first repair quote arrives. Reading is free; writes are a one-time unlock with confirmation and limit checks on every value.

Tag browser in the LineKeeper app: every tag of a ControlLogix or CompactLogix controller with live values and search, read straight from the PLC
The Logix controller hands over its whole tag list — live, searchable
Temporary operator panel in the LineKeeper app standing in for a retired PanelView 600: start and stop push buttons, hold-to-run jog, speed setpoint and status lamps
The temporary panel: start/stop, jog, setpoints, status lamps
Guarded setpoint write in the LineKeeper app: allowed range shown and confirmation required before the value reaches the ControlLogix PLC
Writes are range-checked and confirmed before they reach the PLC
Free app · iPhone & iPad

The 15-minute temporary panel

Zero-config tag browser for Logix, drag-and-drop dashboard, operator panel, alarms — no changes to the PLC program.

Download on theApp Store
QR code — LineKeeper on the App StoreOn a desktop? Scan with your iPhone or iPad to get the free app.
See the app tour →

For the machine itself: the LineKeeper device — in development — is a self-contained 7″ or 10″ touchscreen built to live on the machine permanently — the same drag-and-drop screens, plus what a phone shouldn't carry:

  • Live view of every tag, refreshed twice a second — plus write access with a full audit log
  • Operator panel: start/stop, indicators, setpoints — hold-to-run buttons release safely
  • Stays useful after the repair: data logging, dashboards, machine diagnostics

Small hardware that helps while the panel is out

Amazon affiliate links — they never change the price you pay.

The plug-in LineKeeper device — a 7″ or 10″ touchscreen version of the same idea, with 24/7 logging — is in development ($1,290 planned, one-time). No preorders, no deposits; details on the pricing page.
FAQ

PanelView 600 questions

What replaces a PanelView 600?

Depends which 600 you own — the rear label settles it. Standard 600 (2711-): rebuild on a Plus 7 or PanelView 800, since PanelBuilder32 projects don't convert. Plus/Plus 6 600 (2711P-): a Plus 7, and your .mer application carries forward. Component C600 (2711C-): a PanelView 800, and CCW imports the application.

Is the PanelView Plus 600 obsolete?

Yes — the PanelView Plus 6 line, the 600 included, was discontinued at the end of 2022 (Remote I/O and DeviceNet versions earlier). The Plus 7 is the successor, and the application carries forward with firmware and FactoryTalk View version care.

Will my .mer file run on the replacement panel?

From a Plus/Plus 6 600 to a Plus 7: yes, with attention to firmware and FactoryTalk View versions — and recover the editable .apa archive from the old terminal while it still boots. From a Standard 600 or Component C600: no — those families use different software entirely (rebuild, or CCW import respectively).

Can I keep the machine running while the new panel ships?

Usually yes — the PLC keeps running the machine. The free LineKeeper app for iPhone and iPad connects to CompactLogix and MicroLogix over EtherNet/IP, reads Logix tag lists automatically, and gives the operator live values and start/stop buttons in about 15 minutes, with no PLC program changes.

Ask an engineer

Tell us about your panel

Free remote triage call — often the fault has a workaround that gets you producing before any hardware ships.